Nanoparticle Warfarin + Focused Ultrasound: Hossein Mehrad on Next-Gen Thrombolysis
Hossein Mehrad, Managing Director of Tajhiz Teb Fannavar Parto Company, Director of Mehrad Research Lab, posted on LinkedIn:
”This article investigates the effects of administering Intravenous Lipid-Based Encapsulated Warfarin Nanoparticles on the enhancement of cerebral clot dissolution using Pulsed Low-Level Focused Ultrasound (PLIFU).
The central concept is that combining a Targeted Anticoagulant Delivery system with focused ultrasound stimulation can accelerate and improve the efficiency of Cerebral Thrombolysis. The lipid nanoparticles provide a stable matrix that encapsulates Warfarin Molecules at the nanoscale, preventing their premature degradation in the bloodstream. This nanostructure improves the Pharmacokinetics and Biodistribution of the drug within brain tissue, which naturally shows limited permeability.
The presence of the Lipid Shell enables more effective interaction with Cell Membranes and the Cerebral Microvasculature. Once in circulation, the nanoparticles are exposed to Low-Frequency Pulsed Ultrasound directed at the occluded region. These acoustic waves generate Micro-Mechanical Oscillations and Stable Cavitation around the clot, increasing Tissue Permeability and enhancing Clot Penetration of the nanoparticles. Mechanical stimulation from PLIFU also induces Fibrin Network Disruption, making the clot more responsive to therapeutic activity.
Encapsulated warfarin is released within the clot according to Controlled Release Kinetics, which boosts Targeted Bioavailability and avoids fluctuations in systemic drug concentration. Warfarin further inhibits the Vitamin K-Dependent Coagulation Pathway, preventing clot reinforcement. The integration of chemical inhibition and mechanical ultrasound stimulation results in a significant Synergistic Effect.
Because PLIFU operates at a very low intensity, it minimizes Thermal Damage to cerebral tissue. Overall therapeutic performance depends on Nanoparticle Delivery Efficiency and Acoustic Pressure Amplitude. Animal studies demonstrate faster and more complete clot degradation when nanowarfarin is combined with PLIFU, and Neuroimaging Analysis confirms improved Reperfusion. Effective system design requires precise control of Nanoparticle Size Distribution and Ultrasound Parameters.
This combined strategy represents a promising approach in Non-Invasive Thrombolytic Therapy, with evidence suggesting improved safety, reduced drug dosage, and enhanced clinical outcomes.”

Keep up with Hemostasis Today.
-
Jan 8, 2026, 05:51Dominika Jędrzejewska Akbaş Links Sleep Deprivation, Obesity, and Stroke
-
Jan 8, 2026, 05:42Rob Maloney: A Bruise that Did Not Go Away…
-
Jan 8, 2026, 05:33Matías J Alet on Treating Early Neurological Deterioration in Lacunar Stroke
-
Jan 8, 2026, 05:11Thomas Meinel Shares The English Stroke Guidelines 2026
-
Jan 8, 2026, 05:03Hilla Ben-Pazi: We Were Pleased to Receive a Grant from the Israeli Ministry of Economy
-
Jan 8, 2026, 04:24Nikhil Agrawal Breaks Down Perioperative Anticoagulation
-
Jan 8, 2026, 03:58Louise St Germain Bannon Appointed Interim Executive Director of ISTH
-
Jan 8, 2026, 03:47Wolfgang Miesbach on Fernando Corrales-Medina’s Team’s Latest Cross-Sectional Study on Haemophilia
-
Jan 8, 2026, 03:28Rick Matthews: Powerful Perspective from Erin and the NBCA Team